No Cell Power on Hayward Aqualogic
›
In March of 2009 my Hayward Aqualogic pool system started displaying the message "No Cell Power" and the salt system in my pool wa...
96 comments:
Step 1: Turn off the power
›
Click to enlarge Before beginning, turn off the power to your pool system.
Step 2: Remove the cover
›
Click to enlarge Unplug your salt system. Remove the screws holding the cover in place. Use a screwdriver (if necessary) to lift the cover o...
Step 3: Remove the display unit
›
My display unit was held on with 4 plastic tabs. The two at the top popped out of the main display unit. The two at the bottom popped out ...
Step 4: Locate the K1 element
›
Click to enlarge The K1 element is located in the top-right corner of the main board. The melted join is on the back side of this element.
1 comment:
Step 5: Remove the main board
›
Click to enlarge You may decide to go a different direction here. despite having taken several pictures, I was concerned if I removed all t...
5 comments:
Step 6: Repair the joint
›
Click to enlarge After the screws and tabs were unattached I was able to see the backside of the main board and the melted joint easily stoo...
13 comments:
Step 7: Put it all back
›
Push the main board back onto the plastic tabs. Attach the screws to the main board. Attach the display unit to the plastic tabs. Plug the ...
27 comments:
Saturday, May 2, 2009
A Letter From A Hayward/Goldline Warranty Station
›
I received this helpful letter June 23, 2009. It was sent to me by Loni at Pool Emporium . Pool Emporium is a warranty station for Hayward/...